Functions and Features:
★ 30-call HBW-30 master station can connect 30 substations
simultaneously and 60-call HBW-60 for 60 substations.
★ Easy installation: it requires one 5-wire to connect the master
station and jail substation.
★ All functions of HBT series master station.
★ Main Functions:
● Master station features the functions of detecting the defective
substation, anti-electromagnetic interference and thunderstroke.
● Master station Chinese LCD and menu operation which can display
the states, year, month, date and time.
● Handfree and handset operations between control room and jail.
● The voice processing technology is adopted with master station,
when the substation is alarming, the master station will announce in
voice, the controller will get the alarming substation no. without
check of the master.
● Broadcast function with the master station with the music input
port. It can power on and alarm to the substation timely.
● Alarms from multi substations can be displayed by master station
kept the alarming state.
● The master station can circular monitor each substation and can
not be found by the substations.
● The master station can intercom with multi substation
simultaneously. (Group call and All call)
● Non-stop alarm: in any states of Standby, Talk, Broadcast or
Circular monitor, the master station can receive the alarm from the
substation and announce the corresponding voice prompt.
● The master station can be connected in parallel, the same bus can
be connected with three master stations.
● Unlock function with the master station which can be coordinately
used with the electric controlled lock to control the open and close
of the jail doors.
● Alarm output port with the master station which can be connected
with the alarming horns and sirens.
● Communication interfaces 485 with the master station.

Installation and Operation:
Ⅰ. Hardwares:
1. Master station speaker
2. Handle microphone
3. LCD
4. Power switch (POWER)
5. Broadcast/▼
6. Monitor/▲
7. Function key
8. Handfree talk key (TALK)
9. Selected floor switch
10. Selected floor indicator light
11. Selected substation switch
12. Selected substation indicator light
Ⅱ. Technical Parameters:
30路主机
60路主机
供电电压:AC220±10% 、DC18V3A
AC220±10% 、DC18V3A
纹波系数:5%
5%
静态功耗:4W (VA)
6W (VA)
工作状态功耗:6W (VA)
8W (VA)
音频输出功率:2W THD 10%
2W THD 10%
喇叭阻抗:20Ω
20Ω
音量调节范围:40dB
40dB
音频频率响应:100Hz - 10KHz
100Hz - 10KHz
广播信号输入电平:1V
1V
监听范围:30M²
30M²
控制信号方式:FSK
FSK
控制信号发射电平:10V - 18V
10V - 18V
控制信号接收电平:>=10V >=10V
控制信号波特率:1200bps
1200bps
话筒输入灵敏度:-44±1dB 全向
-44±1dB 全向
通话方式:手柄或免提
手柄或免提
循环监听时间:每路5秒
每路5秒
呼叫分机方式:可单呼、组呼或群呼
可单呼、组呼或群呼
广播状态功耗:45W [带30个分机时]
60W [带60个分机时]
环境温度:-10℃---+80℃
-10℃---+80℃
工作温度:-5℃---+40℃
-5℃---+40℃
外接数据口:232/485 232/485
外接数据口波特率:2400bps
2400bps
最大管理级别:4级
4级
Output power of master station: 800mW 800mW
Master station dimension: 305x210x75mm(LxWxH)
通讯距离(接满30个分机,含广播功能): 200m(0.5mm2); 300m(0.75mm2);
400m(1.0mm2)。 用0.75mm2的线,加中继盒最大可达到2000米。
通讯距离(接满60个分机,含广播功能): 100m(0.5mm2); 150m(0.75mm2); 200m(1.0mm2)。
用0.75mm2的线,加中继盒最大可达到2000米。

Ⅲ. Installation and Operation:

1) Connecting power
Connect the DC18V transformer (included, no polarity) to +/-
connectors on the rear of the master station correctly. Depress the
power switch. Year, month, day and time will display on the LCD. The
power is in normal working status.
2) Testing master station and substation
Testing master station: Depress the power switch on the panel of
master station after connecting it to power source. The master
station will start self test and test each substation one by one
from No. 1 substation. Corresponding indictor light will flash one
if the tested substation is in normal working status. And the
indicator light will lighten and keep in bright green if otherwise.
After testing all substations, the bright green indicator light will
go out after five seconds. The master station will return to normal
status automatically after testing.
3) Alarm and talk
Corresponding router indicator light of the master station will
flash in red if a substation is calling. And calling substation
number will display on the LCD, music prompt will sound and the
system will broadcast calling number. You can talk to the calling
substation by depressing corresponding router switch on the master
station, picking up microphone and substation. (Note: Master station
can talk by depressing the hands free key; Master station can listen
by releasing the hands free key. Talk from master station can be
heard by substations after 0.5 second by using hands free key for
the first time.)
4) Monitor and circular monitor
Monitor: Depress the router switch on the panel of master station to
monitor corresponding substation. Eject the router switch to cancel.
Circular monitor: Depress the monitor switch of master station in
standby status for two seconds to monitor substations circularly
(each substation will be monitored for five seconds). Depress the
monitor switch again for two seconds to cancel circular monitor.
5) Group call, all call
Group call:
Select No.1-5 substations by picking up handset and depressing No. 1
router switch of master station for two seconds. Corresponding
indicator lights will lighten in green. The master station can talk
to all selected substations with handset at this time. Depress the
No. 1 router switch of master station for two seconds again to
cancel.
Select No.6-10 substations by picking up handset and depressing No.
6 router switch of master station for two seconds; select No.11-15
substations by picking up handset and depressing No. 11 router
switch of master station for two seconds (by analogy). Follow above
method to cancel.
All call:
Press the broadcast key on the master station to select all
substations. The master station can talk and broadcast to all
substations by picking up handset or depressing hands free key.
6) Broadcast function
Audio signal can be input from MUSIC input port on the rear of
master station.
Depress the broadcast key. All router indicator lights of
substations will lighten in green. The master station can broadcast
or play background music at this time. “Broadcast status…” will
display on the LCD of master station. Corresponding indicator light
will lighten in red green if a substation is calling. And voice
prompt of corresponding substation number will sound.
7) Alarm output
The connectors (ARM+, 5) on the rear of master station are alarm
output port. Alarm flash light or speaker can be connected to the
alarm out put port. The alarm of substation will touch off alarm
flash light or speaker if corresponding router switch on the master
station has not been selected.
Notes:
1) Contractors or Installers have the option to preset system
expiration date to ensure collection of payments.
2) Monitor can not be found by substations.
3) When powered on, if the master station can not select any
substation, check each grounding wire (No. 5 wire) of each
substation connected on the cable. If any grounding wire has nor
been connected correctly, above malfunction will happen.
|