Download Brochure

ABOUT LONBON

ALL PRODUCTS

NEW PRODUCTS

CASE  STUDY

CONTACT  US

中文

LONBON  INTERCOM
 

Bank/Window Intercom Kits

 

Bank/Window Intercom Kits w
Customer Scoring

 

Intercoms for  Commercial and
Institutional Applications

 
Elevator exclusive intercom system  

Intercoms for Apartments and Schools Intercoms

 

Healthcare and Nurse Calls Applications

 
Hospital ICU visiting system  

Intercoms for Correctional Applications

 

Intercoms for Correctional Visitation Applications

 

Digital and Analog 
Recording Cards

 
Wireless Paging System  
     

LONBON QUEUING

 

Wired Queuing Machine with Touch Screen

 

Wireless Queuing Machine with Touch Screen

 
PC-controlled Queuing System  

Hospital Diagnosis Queuing System

 

Hospital Medicine Taking Ticketer System  
Hospital Auto Registering Machine  
     

LONBON  ALARM

 

Burglary Alarm Set

 

Burglary Alarm

 

Alarm Sensors

 

Magnetic Contacts

 

Alarm Buttons

 

Horns & Sirens

 
Switch & Doorbell  

Accessories

 
   
 
 

       

 

 Your current page :Home -〉LonBon New Products

New  Products

       LonBon—succeed bank/window intercom kits, intercoms for commercial and institutional applications, intercoms for apartments and schools intercoms, healthcare and nurse calls applications, intercoms for correctional applications, intercoms for correctional visitation applications, digital and analog recording cards, queuing system, one after the other new products have:
Ⅰ.Bank/Box Office/Window Intercom Kits (SD Series)
Ⅱ.Bank/Window Intercom Kits w Customer Scoring(SD-2005C Series)

Ⅲ.Elevator exclusive intercom system (DBT Series)

IV.Healthcare and Nurse Calls Applications(NBW Series)
Ⅴ.Hospital ICU visiting system(ICU Series)
Ⅵ.Hospital Diagnosis Queuing System(LB-81-11Y Series)
Ⅶ.Hospital Medicine Taking Ticketer System(LB-81-12Y Series)
Ⅷ.Hospital Auto Registering Machine(LB-81-18 Series)

Ⅸ.Wireless Queuing Machine with Touch Screen(LB-81-16W Series)


     Our company has independent intellectual properties for the calling machine, self researching, developing, producing and selling. The following are these new products' intro:

 1、 Bank/Box Office/Window Intercom Kits (SD Series)
1、Bank/Box Office/Window Intercom Kits (Model:SD-2006DL+):           

Functions and Features:
Bank/window intercom kits SD-2006DL+, master

   station’s appearance is metallic color,and sub

   station is metallic.
Automatic one-to-one 2-way hands-free

   communication, capability is more ascendant than

   SD-2002D.
This product adopts mainframe and more ascendant

   congressional MIC is integrative. Appearance is

   handsome and voice is lifelike, clear and resonant.
Individual volume controls for both master station

   and window sub station.
Can works with LBW series master stations to

   real-time monitor each window’s conversation in

   background (by supervisors), voice is lifelike and clear.
Can work with LBW series master stations to talk

   with master stations. Used by supervisor to provide

   assistance to window service representatives.

   Supervisor talk-in conversation can not be heard by

   window sub stations.
Built-in Recording signal output, can provide master

   station and sub station audio output for recording.
Used in any places where conversations need to be

   assisted.
Power Source Included,Model:988-03  DC6V

   500mA

Master Station Dimensions:150x80x55mm(LxWxH)

Window Substation Dimensions:¢60x15mm(DxH)

MIC's length:360mm.

 

 

  LonBon Patents
      

View Instruction Manual Online SD-2006DL+

            

2、Bank/Box Office/Window Intercom Kits (Model:SD-2006HL+/  SD-2006CL+):           

Functions and Features:
 Bank/window intercom kits SD-2006HL+, appearance

    is black;

    Bank/window intercom kits SD-2006CL+, appearance

    is computer colorr.

  Two specs bank/window intercom in hereinbefore

    have the same function.
Automatic one-to-one 2-way hands-free

    communication.
Has SD-2002CL's all function, voice is more ringing,

     it is be used in noisy location more appliable.
This product adopts mainframe and more ascendant

     congressional MIC is integrative. Appearance is

     handsome and voice is lifelike, clear and resonant.
Sub station has tone arm, could use exterior

     transmitter which is free to talk with master station.
Individual volume controls for both master station

     and window sub station.
Can works with LBW series master stations to

     real-time monitor each window’s conversation in

     background (by supervisors), voice is lifelike and

     clear.
Can work with LBW series master stations to talk

     with master stations. Used by supervisor to provide

     assistance to window service representatives.

     Supervisor talk-in conversation can not be heard by

     window sub stations.
Built-in Recording signal output, can provide master

     station and sub station audio output for recording.
Used in any places where conversations need to be

     assisted.
Can according to customer’s demand, change

 quondam sub station to metallic sub station(model: SD-B)Power Source Included,Model:988-03  DC6V

   500mA

Master Station Dimensions:150x80x55mm(LxWxH)

Window Substation Dimensions:100x55x80mm(LxWxH)

MIC's length:360mm.

 

 LonBon Patents
  
  

View Instruction Manual Online SD-2006HL+

            

3、Bank/Box Office/Window Intercom Kits (Model:SD-2002CL+/  SD-2002DL+/ SD-2002HL+):     

Functions and Features:
Bank/window intercom kits SD-2002HL+, appearance

    is black;

    Bank/window intercom kits SD-2002DL+, appearance

    is metallic color;

    Bank/window intercom kits SD-2002CL+, appearance

    is computer colorr.

    Three specs bank/window intercom in hereinbefore

    have the same function:
Automatic one-to-one 2-way hands-free

     communication, capability is more ascendant than

     SD-2002C and SD-2002D.
This product adopts mainframe and more ascendant

     congressional MIC is integrative. Appearance is

     handsome and voice is lifelike, clear and resonant.
Individual volume controls for both master station

     and window sub station.
Can works with LBW series master stations to

     real-time monitor each window’s conversation in

     background (by supervisors), voice is lifelike and

     clear.
Can work with LBW series master stations to talk

     with master stations. Used by supervisor to provide

     assistance to window service representatives.

     Supervisor talk-in conversation can not be heard by

     window sub stations.
Built-in Recording signal output, can provide master

     station and sub station audio output for recording.
Used in any places where conversations need to be

     assisted.
Can according to customer’s demand, change

 quondam sub station to metallic sub station(model: SD-B)

Power Source Included,Model:988-03  DC6V

   500mA

Master Station Dimensions:130x110x40mm(LxWxH)

Window Substation Dimensions:93x88x18.5mm(LxWxH)

MIC's length:360mm.


  LonBon Patents
     

View Instruction Manual Online SD-2002CL+

     【CEauthentication pass

4、Bank/Box Office/Window Intercom Kits (Model:SD-2001CL+): 

Functions and Features:

Automatic one-to-one 2-way hands-free

   communication, capability is more ascendant than

   SD-2001C+, appearance is computer color.
This product adopts mainframe and more ascendant

   congressional MIC is integrative. Appearance is

    handsome and voice is lifelike, clear and resonant.
Individual volume controls for both master station and

   window sub station.
Can works with LBW series master stations to

   real-time monitor each window’s conversation in

   background (by supervisors), voice is lifelike and clear.
Can work with LBW series master stations to talk

   with master stations. Used by supervisor to provide

   assistance to window service representatives. 

   Supervisor talk-in conversation can not be heard by 

   window sub stations.
Built-in Recording signal output, can provide master

   station and sub station audio output for recording.
Record and play back to substations 4

   frequently-used announcements. Announcements can

   be erased and re-recorded at any time. Power outrage

   memory protection.
Used in any places where conversations need to be

   assisted.
Can according to customer’s demand, change

 quondam sub station to metallic sub station(model: SD-B)

Power Source Included,Model:988-03  DC6V

   500mA

Master Station Dimensions:140x138x55mm(LxWxH)

Window Substation Dimensions:86x84x23mm(LxWxH)

MIC's length:360mm.

 

 

 

 

 

 

   

    

View Instruction Manual Online SD-2001CL+


欲了解更多该系列产品的资料,请点击这里>>>>>

 2、Bank/Window Intercom Kits w Customer Scoring

1、The customer evaluation intercom(model: SD-2005C): 

Functions and Features:

Including all functions of  SD—2002C model, It is

   more comprehensive than SD-2005L in function.
Optional video camera can be installed inside the

   external substation to monitor and record the

   surroundings.

Customer can choose from "Very Satisfied",

   "Satisfied", "Somehow Satisfied", and Dissatisfied".

When needed, the identification of the clerk on duty

   can be displayed on the external substation LCD.

The evaluator has the voice reminder: the sound
   generated by the micro-computer is clear and natural.
The evaluator has the “one-meter line” reminding
   voice.
The IC card records and keeps the evaluation data
   them. When another month comes, the card can  
   file the data automatically and clear the data.
It has the clock function  and can show minute, hour,

   day, month and year
The characters displayed by the internal and external
   LED is clear and up to four figures can be displayed
It has 485 interface and can connect with the
   computer through the network line, which has the
   network monitor function. It can operate the
   complement monitor software tomonitor in real time

   the staff, and the evaluation data, and collect the data.
   It can also dispense the recognition card, read the

   recognition card, collect the data and make the

   monthly report.

Power Source Included,Model:988-03  DC6V

   500mA

Master Station Dimensions:160x106x46mm(LxWxH)

Window Substation Dimensions:150x100x30mm(LxWxH)

 

 

 

 

 

 

 

 

 

Details about SD-2005C The customer evaluation intercom

The products with the patent should not be imitated, or you’ll take law responsibilities.       

欲了解更多该系列产品的资料,请点击这里>>>>>

 3、 Elevator exclusive intercom system (DBT Series)
1、The 20-call master station(model: DBT-20):

Functions:
It can show the alarm from the 20-call substations in

   the elevator room and in the control room and keep

   the alarm in memory.
The effect of the DBT-40 master station can be

   achieved when it is connected with the DBT-20G

   substation.
The master station can detect the substation in the

   elevator room.
The master station and the substation in the elevator

   room can call and talk back mutually.
It can display the alarm from the control room and

    talk back to the substation.
The talkback can be carried on among the substation

    in the elevator room and the substation in the control

    room
The master station has the function to broadcast

    music in the substation in the elevator room.
It can monitor the substation in the elevator room in

   circulation.

 主机与轿厢、机房分机之间每二十路用一条四芯总

    线连接。
●  It is specially used for the talkback among the

    elevator room, the elevator control room and the

    managerial center.
The model of the attached power source: HBT-20-05

   DC18V 2.5A
Size: 220x200x55mm(LxWxH)

Details about  the 20-call master station

2、The substation in the elevator room (DBT-A):

Functions:

分机外观镀铬工艺,防电磁干扰。广播级通话音质,

   放音逼真、清晰。

  It adopts the binary-system coding mode and the

    sound is lively and clear.
  It can alarm to the master station in the control room

    and can talk back to each other.
  The talkback between the substation and the

    machine room can be carried on.
  The talkback among the substation in the machine

    room and the master station and the substation in

    the elevator room can be carried on.
与主机之间每二十路用一条四芯总线连接。
  Size: 130x110x40mm(LxWxH)

Details about The substation in the elevator room

3、The Semi-Flush substation in the elevator room (DBT-B): 

Functions:

超薄分机DBT-B,体积小巧,外形美观。

  It can alarm to the master station in the control room

    and can talk back to each other.
  The talkback between the substation and the

    machine room can be carried on.
  The talkback among the substation in the machine

    room and the master station and the substation in

    the elevator room can be carried on.
与主机之间每二十路用一条四芯总线连接。
  Size: 115x75x18mm(LxWxH)

Details about The substation in the elevator room

4、The substation in the machine room(model: DBT-D): 

Functions:

It adopts the binary-system coding mode and the

   sound is lively and clear.
It can alarm to the master station in the control room.

   The talkback among three parts can go on.
It can choose the substation in the elevator room and

   talk back to each other.
When it is used with the substation in the elevator

   room it has the alarm function.
与主机之间每二十路用一条四芯总线连接。
Size: 140x138x55mm(LxWxH)

Details about The substation in the machine room

欲了解更多该系列产品的资料,请点击这里>>>>>

 4、Healthcare and Nurse Calls Applications(NBW Series)

1、The 30-call master station(model: NBW-30):

Functions and Features:

NBW-30 Master Station can have up to 30 

   Substations. Professional-class sound quality,

   crsipy clear.
The master station can diagnoze substations and

   can also detect short circuits.
The master station had the LCD with Chinese  

   characters. Its operation menu makes it very

   convenient. It also can display the time, date, the

   Intercom number of the bed and the status of the

   system, and so on.
The master station can synchronically display the

   Intercoms from several substations and have the

   memory function. On any condition such as the

   standby, the Intercom, the broadcasting, the

   substation can normally Intercom in.
 When the substation Intercoms the master station,

    the master station will shine its LED’s indicator,

    release music and the voice broadcasting “XX

    emergency Intercom” .
The master station can be set with the nurse levels,

   namely, the particular nurse, the senior nurse and the

   common nurse, according to the illness conditions of

   patients.
One master station can connect to up to 32 corridor

   displays simutaneously.

Easy installation. The master station and substations

   can be connected only with a two-core cable.he max

   communication distance is up to 1000m.
The model of the enclosed power: NBW-30-60

   DC36V1000mA
Size: 305x210x75mm(LxWxH)

download installation and operation manual

Details about the 30-call master station

The products with the patent should not be imitated, or you’ll take law responsibilities.  
                                   

2、The 30-call patient organizer board (Model: NBW-30P):

Functions and Features:
●  Alloy panel is adopted through digital control with

   beautiful and generous appearance.
Use with NBW-30 master station to display the

   calling of No. 1-30 substations through LED. And

   voice broadcasting and music prompts can be

   achieved.
No. 1-30 medical record columns. The medical record

  can be inserted into corresponding column according

  to the bed condition of each patient.
Chinese LCD can display time, date, sickbed number

   of calling party and system state etc.
Easy installation. Only a nine-wire cable (included)

   will be used to connect with the master station.

Size:600x400x35mm(LxWxH)

Details about the 30-call patient organizer board

3、The 60-call master station (Model: NBW-60):

Functions and Features:

NBW-60 Master Station can have up to 60 

   Substations.  Professional-class sound quality,

   crsipy clear.
The master station can diagnoze substations and

   can also detect short circuits.
The master station had the LCD with Chinese  

   characters. Its operation menu makes it very

   convenient. It also can display the time, date, the

   Intercom number of the bed and the status of the

   system, and so on.
The master station can synchronically display the

   Intercoms from several substations and have the

   memory function. On any condition such as the

   standby, the Intercom, the broadcasting, the

   substation can normally Intercom in.
 When the substation Intercoms the master station,

    the master station will shine its LED’s indicator,

    release music and the voice broadcasting “XX

    emergency Intercom” .
The master station can be set with the nurse levels,

   namely, the particular nurse, the senior nurse and the

   common nurse, according to the illness conditions of

   patients.
One master station can connect to up to 32 corridor

   displays simutaneously.

Easy installation. The master station and substations

   can be connected only with a two-core cable.he max

   communication distance is up to 1000m.
The model of the enclosed power: NBW-30-60

   DC36V1000mA
Size: 305x210x75mm(LxWxH)

download installation and operation manual

The products with the patent should not be imitated, or you’ll take law responsibilities.                               

4、The 60-call patient organizer board (Model: NBW-60P):

Functions and Features:

●  Alloy panel is adopted through digital control with

   beautiful and generous appearance.
Use with NBW-60 master station to display the

   calling of No. 1-60 substations through LED. And

   voice broadcasting and music prompts can be

   achieved.
No. 1-60 medical record columns. The medical

   record can be inserted into corresponding column

   according to the bed condition of each patient.
Chinese LCD can display time, date, sickbed number

   of calling party and system state etc.
Easy installation. Only a nine-wire cable (included)

   will be used to connect with the master station.

Size:600x400x35mm(LxWxH)

  

    

5、嵌入式分机(型号:NBW-A):                        

Functions and Features:
  嵌入式分机NBW-A,体积小巧,外形美观,依据国

    标86盒设计尺寸,含安装底盒,可嵌入式安装在医

    院病床上方的设备带上或墙壁上
●  Professional-class sound quality,  crsipy clear.
 Binary coding method is adopted on the substation.

    Substation number can be set arbitrarily.
Bedside substation can call nurse master station and

   talk.
Hand-held caller can be installed on the substation.

   The master station will broadcast the substation

   number when the substation is calling the master

   station.
There is transfusion alarm interface on the substation.

   The substation will alarm the master station

   automatically when the transfusion is over. There are

   alarm, flashing light and voice prompt of “No. XX

   transfusion over”.
Press the Emergency button to call the master

   station in emergency. 
The max communication distance is up to 1000m.
Size:86x86x45mm(LxWxH)

医院对讲呼叫系统嵌入式分机详细说明

  

6、the ultra thin substation(model:NBW-B):

Functions and Features:
 Binary coding method is adopted on the substation.

    Substation number can be set arbitrarily.
Ultra-thin substation NBW-B with vivid and clear voice.
Bedside substation can call nurse master station and

   talk.
Hand-held caller can be installed on the substation.

   The master station will broadcast the substation

   number when the substation is calling the master

   station.
There is transfusion alarm interface on the substation.

   The substation will alarm the master station

   automatically when the transfusion is over. There are

   alarm, flashing light and voice prompt of “No. XX

   transfusion over”.
Press the Emergency button to call the master

   station in emergency. 
The max communication distance is up to 1000m.

Size:115x75x18mm(LxWxH)

Details about the ultra thin substation

The products with the patent should not be imitated, or you’ll take law responsibilities.                                         

7、Waterproof Pull Cable/Call Button(Model:NBW-AN):

Functions and Features:
It’s generally installed in the toilet of the patients’

   room for emergence call in the toilet.

Adopt the online coding mode to set up codes freely,

   with two alarming ways of the line pulling and the

   key-press.

The water prevention design can prevent the switch

   from the bead and the water fog in the toilet and make

   sure of a normal function in a damp environment.

The station has the voice telling and while emergence

   calling is activated in the toilet.

The indicator on the switch will blink when the switch

   is in the state of alarming. It indicates the nurse room

   has already received the alarming signal if the indicator

   is turned off.
Designed according to the specification of the

   international standard Box 86: Size: 86x86x15mm

   (LxWxH)

 

8、Injection IV Monitor (Model:NBW-G):The confusion alarm system is used with the substation
                                                                       the wiring diagram

Functions and Features:
It can be used with the NBW-B substation, or used

   solely.
It is clipped by the transfusion tube and does not

   touch the confusion. The one-key operation is very

   simple. It can also be used for the blood transport

   alarm.
When the confusion is complete, the alarm voice

   “Bi,Bi” will be sounded and the confusion alarm

   device

   can automatically block up the confusion tube.
When the confusion alarm device is used with the

   NBW-B substation, the signal that the confusion is

   over will be sent to the master station in the nurse

   room through the substation, and at the same time

   the voice “XX Confusion over” will be broadcast.
When it is used with the NBW-B substation, the

   additional power source is required to provide. The

   model of the power source is NBW-G-05 14V2.5A.
When it is used lonely, the additional power source is

   required to purchase. The model of the power source

   is NBW-H-05 12V500mA. Suggested price:3.00 USD
Size: 60x70x45mm(LxWxH)

  

The products with the patent should not be imitated, or you’ll take law responsibilities.                                          

欲了解更多该系列产品的资料,请点击这里>>>>>

 5、Hospital ICU visiting system(ICU Series)
1、Master Station(Model:ICU-515):

Functions and Features:

The master station has Chinese LCD which may

   display various states, time and date, etc. and has

    the functions of programmed control exchanger.
The master station may connect 5-route visiting

   Substations and 15-route sickbed Substations.
The master station may display the calls from visiting

   Substation by LED, listen or transfer to the Substation

   for sickbed.
When the relation talks with the patient, the master

   station may carry out real time listen-in and

   interruption for a certain Substation.  
The master station is delivered together with power

   supply with Model ICU-515-05 and output wattage

   AC100V50mA/AC8V250mA/AC18V2000mA
Size :305x210x75mm(LxWxH)

 

 

Details about Master Station

The products with the patent should not be imitated, or you’ll take law responsibilities.  
                                  

2、Substation(Model: WBT-A):

Functions and Features:

 For the use of the talks between the relations and

    the patients in the ward for critical illness.
The relations may call the master station with such

   Substation to visit the patients.
 When the master station calls to the sickbed, the

    patient may listen with such Substation.
●  Talk at will without pressing the key by the

    Substations or the Substation and master station

    being full duplex intercom.
 Simple installation, each Substation needs only

    two-core wires connected with the master station
Size: 195x65x55mm(LxWxH)

Details about Master Station

欲了解更多该系列产品的资料,请点击这里>>>>>

 6、Hospital Diagnosis Queuing System(LB-81-11Y Series)

1、Computer software (model:LB-81-11Y):    

Functions and Features:
Include: the main control software, communication

   software, statistic software, softdog, 10 paper rolls.

   The calling system, display system, voice system

   and ticket printing are directly controlled by the

   computer.
It synchronously display the current business state

    for the system.
It can input doctor’s information at any time as

   required.
It also can revise or delete the information of doctor

   at any time who are receiving patient.
It can select the doctor according to patient's request.
It can make preferred arrangement for the special

   patients.
It can arrange patient reasonably according to current

   conditions.
It can revise the ticket as required and re-select the

   doctor while keep the original ticket No., maintaining

    the fairness of queuing.
It can automatically save all of material in power

   failure, so as not influence the work in power

   resumption.
With direct thermal line printing, it can print the